These interfacial carriers have been observed with various HTL materials and several anode compositions at voltages such that the HTL is reverse-biased. The cation density at an ITO vertical bar CF(x)vertical bar NPB interface is estimated to be approximately 1 x 10(13)/cm(2), or approximately 10% of a molecular layer. [NPB is 4,4'-bis[N-(1-naphthyl)-N-phenylamino]biphenyl. CF(x) is a fluorocarbon polymer.] The cations represent MGCD0103 the integer charge-transfer states whose presence has been
inferred from ultraviolet photoelectron spectroscopy studies of various conductor vertical bar organic interfaces. Anions of an organic hole-injecting material, 1,4,5,8,9,11-hexaazatriphenylene hexacarbonitrile (HAT-CN) were also observed. Conditions near the injecting contacts often determine the electric field
profile and drive voltage of an OLED. Elucidation of these conditions is important to a complete understanding PF00299804 and detailed modeling of OLED operation. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3525592]“
“Purpose: To determine utility of multiparametric imaging performed at 3 T for detection of prostate cancer by using T2-weighted magnetic resonance (MR) imaging, MR spectroscopy, and dynamic contrast material-enhanced MR imaging, with whole-mount pathologic findings as reference standard.
Materials and Methods: This prospectively designed, HIPAA-compliant, single-institution study was approved by the local institutional review selleck chemicals llc board. Seventy consecutive patients (mean age, 60.4 years; mean prostate-specific antigen level, 5.47 ng/mL [5.47 m g/L]; range, 1-19.9 ng/mL [1-19.9 m g/L]) were included; informed consent was obtained
from each patient. All patients had biopsy-proved prostate cancer, with a median Gleason score of 7 (range, 6-9). Images were obtained by using a combination of six-channel cardiac and endorectal coils. MR imaging and pathologic findings were evaluated independently and blinded and then correlated with histopathologic findings by using side-by-side comparison. Analyses were conducted with a raw stringent approach and an alternative neighboring method, which accounted for surgical deformation, shrinkage, and nonuniform slicing factors in pathologic specimens. Generalized estimating equations (GEEs) were used to estimate the predictive value of region-specific, pathologically determined cancer for all three modalities. This approach accounts for the correlation among multiple regions in the same individual.
Results: For T2-weighted MR imaging, sensitivity and specificity values obtained with stringent approach were 0.42 (95% confidence interval [CI]: 0.36, 0.47) and 0.83 (95% CI: 0.81, 0.86), and for the alternative neighboring approach, sensitivity and specificity values were 0.73 (95% CI: 0.67, 0.78) and 0.