The results further support the use of

equine ocular tiss

The results further support the use of

equine ocular tissues as a model for human fungal keratitis. Studies of the TLR expression together with their cytokine profile induced during equine fungal keratitis may help further clarify the pathogenesis of the disease and possibly lead to the development of new treatment protocols for both equines and humans.”
“To characterize the cell mediated immunity (CMI) induced by the investigational CYD tetravalent dengue vaccine (TDV), we developed a whole-blood, intracellular cytokine staining (ICS) assay and a multiplex assay, each requiring 3 mL of blood. We assessed CMI before and 28 d after a first and third injection of CYD-TDV and one year after the third injection in a subset of 80 adolescents and adults enrolled in a phase II trial in Singapore Selleck GNS-1480 (ClinicalTrial.gov NCT NCT00880893). CD4/IFN gamma/TNF alpha responses specific to dengue NS3 were detected before vaccination. Vaccination induced YF-17D-NS3-specific CD8/IFN gamma responses, without significant TNF alpha, and a CYD-specific Th1/Tc1 cellular response in all participants, which was characterized by predominant IFN gamma secretion compared with TNF alpha, associated with

low level IL-13 secretion in multiplex analysis of peripheral blood mononuclear cells (PBMC) supernatants after restimulation with each the CYD vaccine viruses. Responses were directed mainly against CYD-4 after the first vaccination, and were more balanced against all four serotypes after PF-04929113 the third vaccination. The same qualitative profile was observed buy Cl-amidine one year after the third vaccination, with approximately 2-fold lower NS3-specific responses, and 3-fold lower serotype-specific cellular responses. These findings confirm previous observations

regarding both the nature and specificity of cellular responses induced by CYD-TDV, and for the first time demonstrate the persistence of cellular responses after one year. We also established the feasibility of analyzing CMI with small blood samples, allowing such analysis to be considered for pediatric trials.”
“Objective: Aseptic loosening of artificial knee joints induced by wear particles from a tibial polyethylene (PE) insert is a serious problem limiting their longevity. This study investigated the effects of grafting with our original biocompatible phospholipid polymer 2-methacryloyloxyethyl phosphorylcholine (MPC) on the insert surface.

Methods: The hydrophilicity of the PE surface was determined by the contact angle of a water droplet, and the friction torque was measured against a cobalt-chromium alloy component. The wear amount was compared among PE inserts with or without cross-linking and MPC grafting during 5 x 10(6) cycles of loading in a knee joint simulator. The surfaces of the insert and the wear particles in the lubricant were subjected to electron and laser microscopic analyses. The mechanical properties of the inserts were evaluated by the small punch test.

Comments are closed.