majority CA4P of cells involved in the immune response are, in one way or another, influenced when macrolide antibiotics are administered. Having such an obvious effect on the various aspects of the immune system, macrolides seem to be exceptionally suited for the treatment of chronic inflammatory diseases. Copyright (C) 2010 S. Karger AG, Basel”
“Surgeons’ interest in image and/or robotic guidance for spinal implant placement is increasing. This technology is continually improving and may be particularly useful in patients with challenging anatomy. Only through careful clinical evaluation can its successful applications, limitations, and areas for improvement be defined. This study evaluates

the outcomes of robotic-assisted screw placement in a consecutive series of 102 patients.

Data were recorded from technical notes and operative records created immediately following each surgery case, in which the robotic system was used to guide pedicle screw placement. All cases were performed at the same hospital by a single surgeon. The majority of patients had spinal deformity and/or previous spine surgery. Each planned screw placement was classified as: (1) successful/accurately placed screw using robotic guidance; (2) screw malpositioned using robot; (3) use of robot aborted and screw placed manually; (4) GW4869 in vitro planned screw not placed as screw deemed non essential for construct stability. Data from each case were reviewed by two independent Oligomycin A solubility dmso researchers to indentify the diagnosis, number of attempted robotic guided screw placements and the outcome of the attempted placement as well as complications or reasons for non-placement.

Robotic-guided

screw placement was successfully used in 95 out of 102 patients. In those 95 patients, 949 screws (87.5 % of 1,085 planned screws) were successfully implanted. Eleven screws (1.0 %) placed using the robotic system were misplaced (all presumably due to “”skiving”" of the drill bit or trocar off the side of the facet). Robotic guidance was aborted and 110 screws (10.1 %) were manually placed, generally due to poor registration and/or technical trajectory issues. Fifteen screws (1.4 %) were not placed after intraoperative determination that the screw was not essential for construct stability. The robot was not used as planned in seven patients, one due to severe deformity, one due to very high body mass index, one due to extremely poor bone quality, one due to registration difficulty caused by previously placed loosened hardware, one due to difficulty with platform mounting and two due to device technical issues.

Of the 960 screws that were implanted using the robot, 949 (98.9 %) were successfully and accurately implanted and 11 (1.