8 ml/min was used Detection was carried out at 220 nm The injec

8 ml/min was used. Detection was carried out at 220 nm. The injection volume was 20 μl; analysis was performed at ambient temperature. An accurately weighed quantity of miglitol (10 mg) was transferred to 10 ml volumetric flask and dissolved in water and diluted up to the mark with water to get a 1 mg/ml solution.

The series inhibitors standard solutions were prepared by dilution of aliquots of the standard stock solution with mobile phase to get concentration in the range of 10–50 μg/ml of miglitol. Twenty microliter of the each standard solution was injected to HPLC system. The peak areas were plotted against the corresponding concentrations to obtain the calibration graph. The system suitability is used to verify whether the resolution and reproducibility of the chromatographic system are adequate for analysis to be done. The tests Selleck JQ1 were performed by collecting data from five replicate injections of standard solutions. A 20 μl standard drug solution was injected separately and system suitability parameters Entinostat cell line were recorded. Twenty tablets were weighed and average weight was calculated. The tablets were triturated to a fine powder. An accurately weighed quantity of powder equivalent to 10 mg of miglitol

was transferred to 50 ml volumetric flask. About 20 ml of water was added and sonicated for 15 min; further volume was made up to the mark with same solvent. The resulting solution was filtered and filtrate was appropriately diluted with mobile phase to get approximate conc. of 25 μg/ml of miglitol. Twenty micro liters of the test and standard solutions were injected separately after the equilibration of mobile phase with stationary phase. The chromatograms were recorded upto 8 min and area of each peak was noted. The optimized RP-HPLC method was completely validated according to the procedure described in ICH guidelines and United State Pharmacopoeia for validation of analytical methods. The performance parameters evaluated for the method were linearity, precision, accuracy, limits of detection and quantitation

and ruggedness. Linearity was studied by diluting standard stock solution at five aminophylline different concentrations (n = 3) covering the range of 10–50 μg/ml for miglitol, respectively. A graph was plotted for the concentration of the corresponding drug versus peak area. The correlation coefficient (r2) for each drug was calculated. Repeatability study was carried out by analyzing sample solution six times, at 100% of test concentration within the same day using proposed method. Similarly, the intra and inter day precision was evaluated by analyzing tablet sample on the same day and on different days at different time interval, respectively. The contents of drugs and the % relative standard deviation (% R.S.D.) value were calculated.

Comments are closed.